Standpipe
This section contains 72 1" holes per foot and is used in standard conditions where a 10" flow rate is needed. A built-in adjustable restrictor is molded into the bottom of this unit.
This section contains 72 1" holes per foot and is used in standard conditions where a 10" flow rate is needed. A built-in adjustable restrictor is molded into the bottom of this unit.
This is a holed orange section that is used underground from the tee as a riser extension. It can be cut at different locations (as marked on section) to adjust the height.
This is a 10" new style tee that may be directly to 10" corrugated field tile or dual wall pipe.
This increaser adapts a 8" tee to a 10" riser section.
Cubic feet / second | Water Depth | |
---|---|---|
1 ft | ||
2 ft | ||
3 ft | ||
4 ft | ||
5 ft | ||
6 ft |
Stock 10" Inlet with 72 ‐ 1" Holes/ft (ft3/s)
Stock 10" Inlet with 56 ‐ 1" Holes/ft & 9 - 1"x4" Slots/ft (ft3/s)
Water Depth | Stock 10" Inlet with 72 ‐ 1" Holes/ft (ft3/s) | Stock 10" Inlet with 56 ‐ 1" Holes/ft & 9 - 1"x4" Slots/ft (ft3/s) |
---|---|---|
1 ft | 0.63 | 0.89 |
2 ft | 1.78 | 2.52 |
3 ft | 3.27 | 4.63 |
4 ft | 5.04 | 7.13 |
5 ft | 7.04 | 9.96 |
6 ft | 9.26 | 13.09 |
The capacity charts are based on the following assumptions: